=== 工况  6 === Y- 偶然偏心地震作用下的楼层最大位移

  Floor  Tower    Jmax     Max-(Y)     Ave-(Y)       h
                  JmaxD    Max-Dy      Ave-Dy    Max-Dy/h      DyR/Dy    Ratio_AY
    6      1       928      21.56       18.97         3600.
                   928       2.21        1.94       1/1630.    48.2%       1.00
    5      1       吹冰      19.49       17.16         3600.
                   吹冰       3.26        2.87       1/1103.    36.5%       1.14
    4      1       581      16.31       14.36         3600.
                   581       4.46        3.92       1/ 808.    18.6%       1.36
    3      1       411      11.91       10.48         3600.
                   411       5.28        4.65       1/ 681.     6.0%       1.33
    2      1       241       6.64        5.84         3900.
                   241       5.38        4.74       1/ 725.    60.3%       0.95
    1      1        64       1.26        1.11         2300.
                    64       1.26        1.11       1/1825.    99.9%       0.33

   Y方向最大层间位移角:               1/ 681.(第  3层第 1塔)

  === 工况  7 === X 方向风荷载作用下的楼层最大位移
上一篇:科研大厦消防设计+文献综述+CAD消防图纸
下一篇:分布式光纤传感技术与工程应用研究

四层某校综合楼消防设计

新能源技术在建筑节能中的应用

南京博远机电公司1#办公楼...

安徽省涡阳县污水处理厂建筑与施工报告

盛田食品江苏沭阳有限公...

南京市水碧桥村办公楼土...

南京博远机电公司1#办公楼土建商务标编制

《水浒传》中血腥暴力研...

浅析施工企业保理融资成...

PCI+PID算法直流力矩电机速...

高效课堂教师问卷调查表

MNL模型历史城区居民活动...

提高小學语文課堂朗读教...

遥感土地用变化监测国内外研究现状

小型通用机器人控制系统设计任务书

从企业eHR建设谈管理信息...

大规模MIMO系统的发展研究现状