=== 工况  6 === Y- 偶然偏心地震作用下的楼层最大位移

  Floor  Tower    Jmax     Max-(Y)     Ave-(Y)       h
                  JmaxD    Max-Dy      Ave-Dy    Max-Dy/h      DyR/Dy    Ratio_AY
    6      1       928      21.56       18.97         3600.
                   928       2.21        1.94       1/1630.    48.2%       1.00
    5      1       吹冰      19.49       17.16         3600.
                   吹冰       3.26        2.87       1/1103.    36.5%       1.14
    4      1       581      16.31       14.36         3600.
                   581       4.46        3.92       1/ 808.    18.6%       1.36
    3      1       411      11.91       10.48         3600.
                   411       5.28        4.65       1/ 681.     6.0%       1.33
    2      1       241       6.64        5.84         3900.
                   241       5.38        4.74       1/ 725.    60.3%       0.95
    1      1        64       1.26        1.11         2300.
                    64       1.26        1.11       1/1825.    99.9%       0.33

   Y方向最大层间位移角:               1/ 681.(第  3层第 1塔)

  === 工况  7 === X 方向风荷载作用下的楼层最大位移