The basic equipment includes a hotel room bed, closet, table, generally also equipped with a telephone, TV, alarm clock; and a refrigerator, there are a variety of beverages, wine and snacks, all for a fee, pay at checkout. Rooms are also equipped with electric kettles, cups and coffee, tea bags, milk, sugar, etc. for guests to use.
With increasing levels of our national economy, construction also continued and steady development. And the development of the construction industry compared to previous years, the current developers look a river farther, they are no longer one-sided pursuit of volume rate and how development costs drop too low as possible, but more consideration to people-oriented, develop truly engage comfort, high quality residential and commercial building construction..
In order to meet the needs of the rapid development of international trade, tourism, and urban construction, development of high-rise buildings will not stay past the level of development, particularly for air quality and comfort requirements inside the building will be higher. The new medium-sized commercial buildings have installed the air-conditioning system to improve the quality of the mall to attract more customers. Major cities frequently deployed to war more accelerated the popularity of air conditioning systems in commercial buildings. Commercial buildings continue to increase, level of awareness of indoor air temperature and humidity, cleanliness and air quality issues more attention.. Due to energy shortage, saving more and more people pay attention. There is an urgent need for commercial buildings to install configure energy, health, comfort air conditioning systems to meet people's pursuit of high living standards.
 Graduation selected topic JianChen centered -F zone air conditioning system design and parking fire protection design, the main purpose of the theory with practice, improve the practical ability and the ability to solve problems. Air conditioning design of the hotel building indoor environment has a very important role.
In this paper, the JianChen center - a new eight-story hotel wind load, cooling and heating loads and wet load calculations were accurate and detailed, as air conditioning units, vents and other design selection and duct arrangement provides full and accurate basis. The design of the cooling load of 46kW. As the hotel's room uses simple, but the room used or not uncertain, its different functions in different load bearing, so choose a more energy-efficient air fan coil system, its flexible layout, each room can be adjusted independently at room temperature, when room unoccupied can easily turn off the unit (fan off), does not affect the other rooms, so that the more efficient running costs. The arrangement of the water using a four-pipe, closed, vertical with the process of design, can minimize the resistance loss for the backwater, where the feed water pipe loop resistance loss of the most unfavorable 3.2kpa.
Air conditioning system design used in hospitals in the basement , but also to combine the characteristics of the basement and norms to conform to the wind speed , temperature, humidity, and human comfort , help hospital staff to better and efficient work . So fully consider reasonable airflow , temperature, humidity and pressure control and energy saving measures to make the design more reasonable and in line with national standards, to meet the requirements of owners .
目录
1    绪论    1
1.1 设计目的    1
1.2    设计要求    1
1.2.1 设计计算    1
1.2.2 绘图    1
1.2.3  整理设计文件    1
1.3    设计研究现状和发展趋势    1
2  工程概况和原始资料    2
2.1 工程概况    2
2.2 原始资料    2
2.2.1 室外计算参数    2
上一篇:192m预应力混凝土连续梁桥设计+CAD图纸
下一篇:区空调系统设计及地源热泵系统方案+CAD图纸

上海华漕镇社区图书馆建筑与结构设计

临港张江中心商务办公设计

主跨110m预应力混凝土连续刚构桥设计

杭州未来科技城1号地块BIM设计

某会议综合楼的消防设计

二级公路桐千线公路设计

Midas牛家沟大桥设计4*40m先...

拉力采集上位机软件开发任务书

《醉青春》导演作品阐述

多元化刑事简易程序构建探讨【9365字】

浅谈传统人文精神茬大學...

中国古代秘书擅权的发展和恶变

国内外无刷直流电动机研究现状

谷度酒庄消费者回访调查问卷表

辩护律师的作证义务和保...

浅谈新形势下妇产科护理...

高校网球场馆运营管理初探【1805字】