2 Design standard

The building is located in Shanghai,.There are five floors with a total height of 18.3 meters, a total construction area of 4192.4 square meters.There is a layer of staff canteen on the first floor, the height of it is 3.9 meters. The second floor and above is mainly used for office, the height of them are 3.6 meters. This design is mainly for air conditioning system design for the office.

3 Design basic 

3.1 Design task request and the original information 

According to the Building features, purpose and requirements of the construction unit of Haixing office Building for specific types of hotel design are as follows:

(1) load calculation (mainly carried out gradually when the cooling load) 

(2) according to the consequences and choose the right fan coil equipment 

(3) design AC wind system

(4) design AC water system 

(5) computation of water conservancy 

3.2 References

(1) the civil engineering profession to provide the hotel's civil engineering

(2) heating, ventilation and air-conditioning control norms

(3) energy-saving building design standards

(4) heating ventilation and air-conditioning design specifications

(5) heating ventilation and air-conditioning mapping standards

4 Air conditioning wind system

I use the fan coil system on the first floor(semi central air conditioning system) ,from the second floor to the fifth floor ,i use the all-air system (centralized air conditioning) .Because the middle part of the building is large ,the all-air system can support enough air volume and run safely .And it is easy to repair and manage which can produce a good working environment for the officer .

5 Air conditioning water system

The main tube in the water system is different path tube ,it stands that the water direction of supply pipes and return pipes is different ,and the length of the pipe is all different .The length of the pipe is short and simple .The other air conditioning tube is same path tube ,it stands that the water direction of supply pipes and return pipes is same ,and every tube’s length is same .if we use this kind of system ,it will be easy to manage.  

目录

1 设计参数与资料 1

1.1 工程概况 1

1.2 气象参数 1

1.2.1 室外气象资料 1

1.2.2 室内气象资料 1

1.2.3 围护结构参数 2

2 空调冷负荷计算 3

2.1 系统冷负荷的构成 3

2.2 冷负荷构成及计算原理 3

2.2.1 围护结构瞬时冷负荷 3

2.2.2 光照透过窗户而存在的冷负荷 4

2.2.3 屋面瞬时传热引起的冷负荷 4

2.2.4 围护结构冷负荷 4

2.2.5 光照散发热量造成的冷负荷 5

2.2.6 人体散发冷负荷 5

2.2.7 设备冷负荷 5

2.2.8渗透空气显热冷负 6

2.2.9 食物的显热散热冷负荷 6

2.2.10 散湿量与潜热冷负荷 6

2.2.11新风冷负荷 7

2.3负荷计算结果 8

3  空调系统方案

上一篇:华贸G区空调设计及防排烟设计+CAD图纸
下一篇:12层住宅结构施工图与信息化设计+CAD图纸

南京博远机电公司1#办公楼...

盛田食品江苏沭阳有限公...

南京博远机电公司1#办公楼土建商务标编制

论上市公司會计信息披露问题【8518字】

解读上市公司利润表新变化【2493字】

南京某建筑公司办公楼建筑及结构设计

苏南某县级市规划局五层办公楼设计

提高小學语文課堂朗读教...

浅析施工企业保理融资成...

从企业eHR建设谈管理信息...

MNL模型历史城区居民活动...

小型通用机器人控制系统设计任务书

高效课堂教师问卷调查表

遥感土地用变化监测国内外研究现状

大规模MIMO系统的发展研究现状

PCI+PID算法直流力矩电机速...

《水浒传》中血腥暴力研...