Automatic sprinkler fire extinguishing system adopted wet automatic sprinkler system, the system putted out the fire in time, saved the advantages of high efficiency. Applied to the environment temperature was not lower than 4 ° C, and was not higher than 70 ° C. The system alarm valve group setted in a layer of water pump room; Spray water from fire pool directly extracted by spray pump, a rooftop water tank outside setted pump combination. The volume of the roof water tank was 18 ㎡.
This building used the MF/ABC5 mobile (Ammonium phosphate) ammonium phosphate dry powder fire extinguishers. 1 layer to 2 layer setted 3 tools; The rest setted 2 tools. The total number of the fire extinguisher was18.
4)    Drainage system:
    Living sewage, wastewater used the confluence system, the life sewage, waste water was collected back through the municipal sewage pipe. The special-purpose ventilation tube should be setted in this design . Rainwater system used gutter drainage way, by pooling the back into the municipal rainwater pipe network, didn't confluence with sewage, to avoid increasing the capacity of sewage.    
    Sludge wastewater and vent pipe used UPVC drainage pipe,.The adhesive connection. "De" in diameter. Rain water drainage pipes adopted HDPE pipes. The adhesive connection. "De" in diameter. The advantages of UPVC pipe are: light weight, easy to shipment; Product with excellent acid and alkali resistance, corrosion resistance, long life; Flow resistance small, the pipe inner surface was smooth, high water capacity; Mechanical strength, resistance to water pressure strength, compressive strength, impact strength was good; with not affecting the water quality, didn't cause secondary pollution; Construction was simple, easy to maintain.               HDPE pipe has the advantage : high water security , the orifice was not easy to jam, to ensure smooth system; strong Corrosion resistance and Compressive strength; maintenance cost low,and easy to management.
5)    Energy saving:
    Without affecting the normal use of sanitary ware in the case we should adopt energy-saving new sanitary ware, which can greatly reduce equipment load, reduce the energy consumption.
Water reuse can be used in the design to increase quality life wastewater reuse rate. Technology refers to the district residents living waste water (sewage) (bath, toilet, laundry, kitchen, toilet) centralized processing, reach a certain standard back for the village road virescence water, car wash, rinse, family sit implement flushing, etc., so as to achieve the purpose of saving water.
Keywords: water supply, drainage systems, fire systems, energy saving
目  录
1  引言    1
2  设计概况    1
2.1  设计资料    1
2.2  设计依据及规范    1
2.3  设计要求    2
3  建筑管材的选择    2
3.1  给水管材的选择    2
3.1.1  给水管材的类型    2
3.1.2  给水管材的选择原则    3
3.1.3  给水管材的选择    3
3.2  排水管材的选择    3
3.2.1  排水管材的类型    3
3.2.2  排水管材的选择原则    4
3.2.3  排水管材的选择    4
4  给水系统设计    4
4.1  综述    4
4.2  给水方式的选择    4
4.2.1  直接给水方式    4
4.2.2  水泵水箱联合给水方式    4
4.2.3  分区给水方式    5
4.2.4  给水方式的选择    5
上一篇:大厦空调安装工程预算与施工组织设计
下一篇:公司办公楼空调工程设计+CAD图纸

上海华漕镇社区图书馆建筑与结构设计

临港张江中心商务办公设计

主跨110m预应力混凝土连续刚构桥设计

杭州未来科技城1号地块BIM设计

某会议综合楼的消防设计

二级公路桐千线公路设计

Midas牛家沟大桥设计4*40m先...

浅谈新形势下妇产科护理...

《醉青春》导演作品阐述

多元化刑事简易程序构建探讨【9365字】

高校网球场馆运营管理初探【1805字】

拉力采集上位机软件开发任务书

中国古代秘书擅权的发展和恶变

国内外无刷直流电动机研究现状

谷度酒庄消费者回访调查问卷表

浅谈传统人文精神茬大學...

辩护律师的作证义务和保...