Abstract Solar air heaters are seen as a promising option for reducing the building energy demand in particular when combined with heat pumps。 In this work, a modeling tool to predict the performances of heat pump driven by solar heater is developed。 In particular, the channel between the base of the roof and the tiles is considered。 As a case study, a detached house in northern Italy is taken into consideration。 Results show that the air temperature variation ranges from 2 °C to 20 °C leading to a heat recovered between 2 kW and 7 kW in winter and summer time, respectively。 There is no significant variation of air temperature and heat recovered between the two considered orientation (N-S and E-W), whilst the integration of the PV cell in the tile reduces the thermal energy by 15%。 The heat recovered enhances the heat pump COP reducing the Primary Energy Consumption of a conventional heat pump by 5% achieved with limited additional costs。 The impact of the electricity generated is more important also because the excess can be sold to the grid and not wasted as for the heat recovered in summer time。84893

Keywords: Solar driven heat pump, solar heater, Primary Energy savings, PV tile

Nomenclature

α Absorptivity

β isobaric thermal expansion coefficient [K-1]

ε emissivity

γ cell power temperature coefficient [%/°C]

ρ Density [kg m-3]

θ Incidence angle [°]

el Average electricity generation Efficiency [%]

is,c Isentropic efficiency of the compressor

a,b Friction factor parameters

A Tile area [m2]

BIPV Building Integrated Photovoltaic

BIPV/T Building Integrated Photovoltaic Thermal

c Specific Heat Capacity [kJ kg-1 K-1]

Conv Conventional tile case

COP Coefficient of Performances

Dh Hydraulic Diameter [m]

E Energy [J]

EPI Energy Performance Index

DNI Direct Normal Irradiation [kWh y-1 m-2]

f Friction factor

G Solar Irradiance [W m-2]

GHI Global Horizontal Irradiation [kWh y-1 m-2]

h heat transfer coefficient [W m-2K-1]

k Conductive heat coefficient [W m-1 K-1]

Serenity index

kΔp Pressure drop constant [bar m-2 s2]

1

Page 1 of 22

L Length of the pitch [m]

m Mass flow [kg s-1]

Nu Nusselt Number

p Pressure [bar]

P Electric Power [W]

PEC Primary Energy Consumption

Pr Prandtl number

PV Photovoltaic tile case

Thermal power [W]

R Pressure drop term [J/kg]

上一篇:轻水反应堆建模和复合燃料热特性英文文献和中文翻译
下一篇:微型固体氧化物燃料电池英文文献和中文翻译

太阳能最大功率点追踪和...

太阳能光伏空调散热设计英文文献和中文翻译

全电气化太阳能房屋英文文献和中文翻译

多机风力太阳能混合动力...

太阳能除湿型空调系统英文文献和中文翻译

太阳能跟踪系统英文献和中文翻译

太阳能中央空调英文文献和翻译

上海居民的社会参与研究

AES算法GPU协处理下分组加...

压疮高危人群的标准化中...

从政策角度谈黑龙江對俄...

提高教育质量,构建大學生...

STC89C52单片机NRF24L01的无线病房呼叫系统设计

酵母菌发酵生产天然香料...

浅谈高校行政管理人员的...

浅论职工思想政治工作茬...

基于Joomla平台的计算机学院网站设计与开发