conditions and found that black painted envelopes resulted in up to
7 ◦C (per unit volume of interior space) higher temperature than the
corresponding white painted envelopes. Uemoto et al. [6] showed
that cool colored paint formulations produced significantly higher
near infrared radiation reflectance than conventional paints of sim-
ilar colors, and measured a more than 10 ◦C reduction in surfacetemperatureswhen exposed to infrared radiation. Reagan and Ack-
lam[7] calculated the total building heat gain reduction when roof
surface reflectivity increased from 0.35 to 0.75. In July, the reduc-
tions were 6.4% and 4.8% in Tucson, Arizona with ceiling thermal
resistances of 2.5 and 5.88m2 K/W respectively. Griggs [8] found
up to 65% reduction in heat flux through a white roof compared to
black roof with the same thermal resistances of 1.32m2 K/W.
1.2. Previous experimental studies—the impact of reflective
coatings on energy consumption and peak demand
Several published articles focus on the potential reduction in
energy consumption for air conditioning and peak demand, which
are important parts of energy costs. Energy consumption and peak
demand savings with reflective coatings strongly depend on cli-
matic conditions (except for the envelope and coating material
properties and space type/configuration). Most studies were con-
ducted in California: Akbari et al. [9] compared cooling energy
and peak power consumption of two identical school bungalows
with different roof reflectivities and found a 3.1 kWh (35%) sav-
ings in cooling energy as well as 0.6 kWpeak demand savings with
reflective roofs. They also concluded [10] that increasing the roof
reflectance of commercial buildings in California from about 20%
to 60% decreased the roof temperature on hot summer afternoons
by 7.2 ◦C. In another study [11], they reported electricity savings of
0.5 kWh/day (or 33Wh/m2/day) by increasing roof reflectivity from
26% to 72%, which translates into annual energy savings of about
125 kWh. For the same location, Hildebrandt et al. [12] measured
daily air-conditioning savings of 17%, 26% and 39% in an office, a
museum and a hospital with high reflectivity roofs. Parker et al.
[13]monitored six homes in Florida before and after application of
high-albedo coatings on their roofs. Reduction in air-conditioning
electricity consumption was measured between 11% and 43% with
an average saving of 9.2 kWh/day, and reduction in peak power
demand (occurs between 5 and 6 pm)was 0.4–1.0 kWwith an aver-
age reduction of 0.7 kW. They also monitored seven retail stores
within a strip mall in Florida. After applying a reflective roof coat-
ing, a 7.5Wh/m2 (25%) drop in daily summertime cooling-energy
use and a 0.65W/m2 (29%) decrease in demand were realized [14].
Akridge [15] reported daily savings of 75Wh/m2 (28%) for an edu-
cation building in Georgia by painting the galvanized roof with
white acrylic coating. The same researcher [16] also measured
a reduction of 33 ◦C in peak roof temperature of a single storey
building after application of a thermal control coating. In Nevada,
Akbari and Rainer [17] measured daily air-conditioning energy
savings of 33Wh/m2 (only 1%) in two telecommunication regen-
eration buildings. In Texas, Konopacki and Akbari [18] measured
daily energy savings of 39Wh/m2 (11%) and peak-power reduction
of 3.8W/m2 (14%) in a large retail store when a reflective mem-
brane was used. Energy savings in an office building in Mississippi
reached 22% after application of a reflective roof coating [19].In
Hong Kong, Cheung et al. [20] showed that 30% reduction in solar
absorptance can achieve 12% saving in annual required cooling
上一篇:自然通风英文文献和翻译
下一篇:真空电弧沉积系统英文文献和翻译

AngularJS技术介绍英文文献和中文翻译

开关电源水冷却系统英文文献和中文翻译

减数分裂和基因重组英文文献和中文翻译

太阳能最大功率点追踪和...

移动码头的泊位分配问题英文文献和中文翻译

虚拟船舶装配集成建模方...

中学生科学探究中对等论...

上海居民的社会参与研究

STC89C52单片机NRF24L01的无线病房呼叫系统设计

浅谈高校行政管理人员的...

AES算法GPU协处理下分组加...

提高教育质量,构建大學生...

酵母菌发酵生产天然香料...

浅论职工思想政治工作茬...

基于Joomla平台的计算机学院网站设计与开发

压疮高危人群的标准化中...

从政策角度谈黑龙江對俄...