Abstract This paper reports the results of a research project comparing the effect of surface crack width and degree of corrosion on the bond strength of confined and unconfined deformed 12 and 16 mm mild steel reinforcing bars. The corrosion was induced by chloride contamination of the concrete and an applied DC current. The principal parameters investigated were confinement of the reinforcement, the cover depth, bar diameter, degree of corrosion and the surface crack width. The results indicated that potential relationship between the crack width and the bond strength. The results also showed an increase in bond strength at the point where initial surface cracking was observed for bars with confining stirrups. No such increase was observed with unconfined specimens.34414
Keywords:  bond ;corrosion ; rebar ; cover ; crack width ; concrete
 
1   Introduction

The corrosion of steel reinforcement is a major cause of the deterioration of reinforced concrete structures throughout the world. In uncorroded structures the bond between the steel reinforcement and the concrete ensures that reinforced concrete acts in a composite manner. However, when corrosion of the steel occurs this composite performance is adversely affected. This is due to the formation of corrosion products on the steel surface, which affect the bond between the steel and the concrete.
The deterioration of reinforced concrete is characterized by a general or localized loss of section on the reinforcing bars and the formation of expansive corrosion products. This deterioration can affect structures in a number of ways; the production of expansive products creates tensile stresses within the concrete, which can result in cracking and spalling of the concrete cover. This cracking can lead to accelerated ingress of the aggressive agents causing further corrosion. It can also result in a loss of strength and stiffness of the concrete cover. The corrosion products can also affect the bond strength between the concrete and the reinforcing steel. Finally the corrosion reduces the cross section of the reinforcing steel, which can affect the ductility of the steel and the load bearing capacity, which can ultimately impact upon the serviceability of the structure and the structural capacity [12, 25].
Previous research has investigated the impact of corrosion on bond [2–5, 7, 12, 20, 23–25, 27, 29], with a number of models being proposed [4, 6, 9, 10, 18, 19, 24, 29]. The majority of this research has focused on the relationship between the level of corrosion (mass loss of steel) or the current density degree (corrosion current applied in accelerated testing) and crack width, or on the relationship between bond strength and level of corrosion. Other research has investigated the mechanical behaviour of corroded steel [1, 11] and the friction characteristics [13]. However, little research has focused on the relationship between crack width and bond [23, 26, 28], a parameter that can be measured with relative ease on actual structures.
The corrosion of the reinforcing steel results in the formation of iron oxides which occupy a larger volume than that of the parent metal. This expansion creates tensile stresses within the surrounding concrete, eventually leading to cracking of the cover concrete. Once cracking occurs there is a loss of confining force from the concrete. This suggests that the loss of bond capacity could be related to the longitudinal crack width [12]. However, the use of confinement within the concrete can counteract this loss of bond capacity to a certain degree. Research to date has primarily involved specimens with confinement. This paper reports a study comparing the loss of bond of specimens with and without confinement.

2   Experimental investigation

2.1   Specimens
Beam end specimens [28] were selected for this study. This type of eccentric pullout or ‘beam end’ type specimen uses a bonded length representative of the anchorage zone of a typical simply supported beam. Specimens of rectangular cross section were cast with a longitudinal reinforcing bar in each corner, Fig. 1. An 80 mm plastic tube was provided at the bar underneath the transverse reaction to ensure that the bond strength was not enhanced due to a (transverse) compressive force acting on the bar over this length.
上一篇:IOS APP Store英文文献和中文翻译
下一篇:Servlet与JSP技术英文文献和中文翻译

中学生科学探究中对等论...

学前教育英文文献和中文翻译

微注塑成型工艺参数对成...

土壤应力对桩基桥梁历史...

锈蚀钢筋的力学性能英文文献和中文翻译

齿条刀具对渐开线直齿轮...

基于对象的编程评估英文文献和中文翻译

STC89C52单片机NRF24L01的无线病房呼叫系统设计

浅谈高校行政管理人员的...

酵母菌发酵生产天然香料...

上海居民的社会参与研究

从政策角度谈黑龙江對俄...

浅论职工思想政治工作茬...

基于Joomla平台的计算机学院网站设计与开发

压疮高危人群的标准化中...

提高教育质量,构建大學生...

AES算法GPU协处理下分组加...