or the components connected in the network will function correctly.

Note

Data of the “WORD“ (2 bytes) or "DWORD“ (4 bytes) type are stored in an S7-200

in "big-endian“ format, i.e.

Address n: MSB

Address n+1: LSB (analogous for DWORD).

4.4.1 Occupied system flag area (SM area)

The CP 243-1 occupies 50 bytes in the S7-200 CPU system flag area. The address

of these 50 bytes depends on the position in which a CP 243-1 is currently located

in an S7-200 system. Primarily general information and status information of the

CP 243-1 are stored in these 50 bytes. The last four bytes contain a pointer

through which one can access the CP 243-1 configuration data. These configuration

data is consecutively stored in the S7-200 CPU variables memory. They are

subpided into the:

• Configuration Data Block (CDB)

• Network Parameter Block (NPB)

• Network Data Block (NDB)

The following table shows the relationship between the position of a module in the S7-200 system and the associated system flag area.

 

Table 2: System flag area

Note

When using firmware version less than 1.20 then the CP 243-1 must be in position

0 (next to the CPU) or it may be in position 1 if another intelligent module occupies

position 0.

4.4.2 Structure of the Configuration Data Blocks (CDB)

The CDB is generated by the Ethernet Wizard in STEP 7 Micro/WIN 32. The following

table shows the structure of the CDB.

 

 

 

 

4.4.3 Structure of the Network Parameter Blocks (NPB)

This data block is generated by the CP 243-1 itself in accordance with the current

set of network parameters. It contains the TCP/IP parameter values currently in

use, provided the CP 243-1 has been correctly configured. In the event of a configuration

error, the NPB will not contain any valid data.

 

4.4.4 Structure of the Network Data Blocks (NDB)

The NDB is generated by the Ethernet Wizard in STEP 7 Micro/WIN 32. The

read/write commands possible for clients are configured in this data bock. Up to 32

read/write commands can be configured for each of the 8 possible communication

channels. If the CP 243-1 is operated on a channel as a server, then there is no

entry in the NDB structure for this channel.

The following table shows the structure of the NDB. The codes for read/write commands

are represented by the letters n, m, p = 0, ..., 31, and the channel codes are

represented by the letter r = 0, ...,7.

 

 

4.5 Configuring a communication partner with STEP 7

Using the S7-300 system as an example, the following section outlines the steps

you need to take in STEP 7 to configure the system for communication with an

S7-200 system via the associated Ethernet communications processor. The procedure

for the S7-400 system is similar.

For the exact configuration steps, please refer to the STEP 7 description (MLFB:

6ES7 810-4CC05-0YX0) or the handbooks for the CP 343-1 and the CP 443-1.

In S7-300 and S7-400 systems, a distinction is made between configured and free

connections. For configured connections, the connection parameters are specified

by the user. In contrast, free connections do not have to be configured in STEP 7.

Configured connections

If you would like to work with a configured connection, you must first insert a new

S7 connection in the STEP 7 NetPro program package. In the "Insert new connection"

mask, specify the type of station with which you would like to establish a connection.

上一篇:振动台实验和动态响应地震后的钢筋混凝土建筑英文文献和中文翻译
下一篇:机床结构动态性能预测英文文献及中文翻译

开关电源水冷却系统英文文献和中文翻译

减数分裂和基因重组英文文献和中文翻译

太阳能最大功率点追踪和...

移动码头的泊位分配问题英文文献和中文翻译

虚拟船舶装配集成建模方...

中学生科学探究中对等论...

车辆路面相互作用动力学英文文献和中文翻译

淮安市老漂族心理与休闲体育现状的研究

浅谈动画短片《天降好运》中的剧本创作

大学生就业方向与专业关系的研究

弹道修正弹实测弹道气象数据使用方法研究

小学《道德与法治》学习心得体会

组态王文献综述

人事管理系统开题报告

紫陵阁

适合宝妈开的实体店,适...

林业机械作业中的安全性问题【2230字】