Deteriorationof the interface increases with the increase in the cementdosage. According to test results, although the variation ofcement dosage affects the strength and durability of concreteat ambient temperature, it does not affect the relative residualstrength of concrete exposed to high temperature. The rela-tive residual compressive and flexural strength–temperaturerelationships of concrete were found not to depend on thecement dosages used in this investigation.(2) The compressive and flexural strength–temperature relation-ships can be characterized by two stages:(3) Stage 1: Minor strength loss stage between room temperatureand 200 1C.(4) Stage 2: Major strength loss stage, which begins at a tem-perature of about 400 1C.(5) Comparisons between the experimental residual compressivestrength and the predicted residual compressive strengths asobtained by the BS EN 1992-1-2:2004 and ACI 216-1 weremade. It was found that the relative residual compressivestrength of experimental results agree better with the pre-dicted results in given ACI 216-1 for temperature under400 1C and they agree better with the predicted results ingiven BS EN 1992-1-2:2004 for exceeding 600 1C.(6) Mathematical equations were proposed to predict the resi-dual compressive and flexural strengths of concrete with hightemperatures. These equations can be used to assess the post-fire strength of concrete structures made with concrete mixestypically used in Turkey.(7) The VUT test is found to be an effective tool to assess thedegree of damage in concrete structures exposed to fire.References[1] M.S. Akman, Building Damages and Repair Principles, Turkish Chamber ofCivil Engineers,_ Istanbul, Turkey, 2000 (in Turkish).[2] C.A. Menzel, Tests of the fire resistance and thermal properties of solidconcrete slabs and their significance, Proc. Am. Soc. Test. Mater. 43 (1943)109–1153.[3] C.R Binner, C.B. Wilkie, P. Miller, Heat Testing of High Density Concrete,supplement, Declassified Report HKF-1, U.S. Atomic Energy Commission, June1949.[4] H.L. Malhotra, The effect of temperature on the compressive strength ofconcrete, Mag. Concr. Res. (London) 8 (22) (1956) 85–149.[5] J. Xiao, G. K¨ onig, Study on concrete at high temperature in China—anoverview, Fire Saf. J. 39 (2004) 89–103.[6] ACI 216.1. Standard Method for Determining Fire Resistance of Concrete andMasonry Construction Assemblies (AC- 216.1-07/TMS 0216.1-07), AmericanConcrete Institute, Farmington Hills, MI, 2007.[7] N. Y¨ uzer, F. Ak¨ oz, L. Dokuzer O ¨ zt ¨ urk, Compressive strength–color changerelation in mortars at high temperature, Cem. Concr. Res. 34 (2004)1803–1807.[8] World Trade Center: Building Performance Study: Data Collection, PreliminaryObservations, and Recommendations, FEMA, Report # 403, May 2002.[9] A. Behnood, H. Ziari, Effects of silica fume addition and water to cement ratioon the properties of high-strength concrete after exposure to high tempera-tures, Cem. Concr. Compos. 30 (2008) 106–112.[10] C.S Poon, S. Azhar, M Anson, Y. Wong, Comparison of the strength anddurability performance of normal and high-strength pozzolanic concretes atelevated temperatures, Cem. Concr. Res. 31 (2001) 1291–1300.[11] M.A.H Khandaker, High strength blended cement concrete incorporatingvolcanic ash: performance at high temperatures, Cem. Concr. Compos. 20(2006) 535–545.[12] O ¨ Arı ¨ oz, Effects of elevated temperatures on properties of concrete, Fire Saf. J.42 (2007) 516–522.[13] M.A. Youssef, M. Moftah, General stres–strain relationship for concrete atelevated temperatures, Eng. Struct. 29 (2007) 2618–2634.[14] M. Husem, The effects of high temperature on compressive and flexuralstrengths of ordinary and high-performance concrete, Fire Saf. J. 41 (2006)155–163.[15] I.A. Fletcher, S. Welch, J.L. Torero, R.O. Carvel, A. Usmani, Behaviour ofconcrete structure in fire,
Therm. Sci. 11 (2) (2007) 37–52.[16] L. Biolzi, S. Cattaneo, G. Rosati, Evaluating residual properties of thermallydamaged concrete, Cem. Concr. Compos. 30 (2008) 907–916.[17] M. Li, C.X. Qian, W. Sun, Mechanical properties of high-strength concreteafter fire, Cem. Concr. Res. 34 (2004) 1001–1005.[18] Report No: NISTIR 5934. Fire Performance of High Strength Concrete: AReport of the State-of-the-Art, by L.T. Phan, Building and Fire ResearchLaboratory, NIST Gaithersburg, MD 20899; Dated December 1996.[19] A.M. Neville, Properties of Concrete, Halsted Press, John Wiley & Sons Inc.,New York, 1973.[20] B. Georgali, P.E. Tsakiridis, Microstructure of fire-damaged concrete, A casestudy, Cem. Concr. Compos. 27 (2005) 255–259.[21] BS EN 1992-1-2:2004 Eurocode 2: Design of Concrete Structures. GeneralRules. Structural Fire Design, European Committee for Standardization,Brussels, 2005.[22] EN-197/1. Cement. Composition, Specifications and Conformity Criteria forCommon Cements. British-Adopted European Standard, 2000.[23] TS EN 206-1. Concrete—Part 1: Specification, Performance, Production andConformity. Turkish Standards Institute, Ankara, 2002.[24] E. Tolentino, et al., Effects of high temperature on the residual performance ofportland cement concretes, Mater. Res. 5 (3) (2002) 301–307.[25] ASTM E 119-00A. Standard Test Methods for Fire Tests of Building Construc-tion and Materials, ASTM International, West Conshohocken, PA, 2000.[26] GTG. Mohamedbhai, Effect of exposure time and rates of heating and cooling onresidual strength of heated concrete, Mag. Concr. Res. 38 (136) (1986) 151–158.[27] L.T. Pham, Fire Performance of High Strength Concrete, A Report of the Stateof the Art, Building and Fire Research laboratory, National Institute ofStandards and Technology, MD, 1996.[28] ASTM C597–09. Standard Test Method for Pulse Velocity Through Concrete,ASTM International, West Conshohocken, PA, 2009, doi: 10.1520/C0597-09,www.astm.org .[29] ASTM C78/ C78M - 10 Standard Test Method for Flexural Strength ofConcrete (Using Simple Beam with Third-Point Loading). ASTM International,West Conshohocken, PA, 2009, doi: 10.1520/C0078_C0078M-10, www.astm.org .[30] BS EN 12504-1:2009. Testing Concrete in Structures. Cored Specimens.Taking, Examining and Testing in Compression, European Committee forStandardization, Brussels, 2009.[31] S.Y.N Chan, G.F. Peng, M. Anson, Residual strength and pore structure of high-strength concrete and normal-strength concrete after exposure to hightemperatures, Cem. Concr. Compos. 21 (1999) 23–27.[32] W.M. Lin, T.D. Lin, L.J. Powers-Couche, Microstructure of fire-damagedconcrete, ACI Mater. J. 93 (3) (1996) 199–205.[33] M. Colombo, R. Felicetti, New NDT techniques for the assessment of fire-damaged concrete structures, Fire Saf. J. 42 (2007) 461–472.[34] G. Durmus -, M. Arslan, The effect of high temperature on pore structure ofconcrete, in: 5. International Advanced Technologies Symposium (IATS’09),13–15 May 2009, Karab ¨ uk, Turkey (in Turkish).[35] Y.N. Chan, X. Luo, W. Sun, Compressive strength and pore structure of high-performance concrete after exposure to high temperature up to 800, Cem.Concr. Res. 30 (2000) 247–251. 
上一篇:耦合侧向扭转频率的不对称三维框架结构英文文献和中文翻译
下一篇:在平衡的轴向荷载下K型管节点对应力集中系数英文文献和中文翻译

中学生科学探究中对等论...

学前教育英文文献和中文翻译

微注塑成型工艺参数对成...

土壤应力对桩基桥梁历史...

齿条刀具对渐开线直齿轮...

基于对象的编程评估英文文献和中文翻译

U型弯曲部分工艺对中心式...

上海居民的社会参与研究

从政策角度谈黑龙江對俄...

AES算法GPU协处理下分组加...

酵母菌发酵生产天然香料...

浅谈高校行政管理人员的...

提高教育质量,构建大學生...

STC89C52单片机NRF24L01的无线病房呼叫系统设计

浅论职工思想政治工作茬...

压疮高危人群的标准化中...

基于Joomla平台的计算机学院网站设计与开发