• Bolt force due to moment is proportional to the distance from the bolt to the centroid of the bolt group (Fig. 9(a)).

• The axial and shear force is subpided equally between the number of bolts (Fig. 9(b)). The design calculations shows that six, M20 Grade 8.8 high strength bolts are adequate for the eaves and apex joints of the portal frames. Grade 8.8 bolts have a minimum tensile stress fu=800 MPa.  2a result of the applied moment Mu, Fa is the axial force, Fs is the shear force, Fx is the bolt force in x-direction,

and Fy is the bolt force in y-direction. The forces for bolts 1 and 4 are determined from the same expressions and a bolt angle of α. Bolts 3 and 6 are lightly loaded (Fig. 5) and are therefore not critical. The moments due to the ultimate loads (Mux) at the eaves joints and the moment of resistance of the joints (Mrj) of the three frames are presented in Table 8. Parameter r1 and r2 are distances from bolt 1 and bolt 2 to the centroid of the group of bolts respectively. Mrj is evaluated, based on the bearing resistance of the plate (Br), which in all cases is much less than the shearing resistance of the bolts. Bearing capacity (resistance) of the connections is established from the following equation:

Br=φatfu≤φCdtfu (9)

where, φ is the bearing resistance factor (0.67), t is the thickness of the channel, d is the diameter of bolt, fu is the minimum tensile strength of the channel and a is the distance from centre of hole to the edge towards which the force is directed. Based on the design recommendation of Kemp (2001), a coefficient C of 1.8 for a standard washer under the nut and bolt head is used in bearing resistance calculations. The coefficient represents a lower bound value rather than the mean value for interpreting test results. This factor depends on the ratio of bolt

diameter to member thickness. The design calculations in the code shows that six, M20 Grade 8.8 high strength bolts are adequate for the eaves and apex joints of the

portal frames (Table 8).

8.2. Base connection

The base connection in Fig. 2 is designed for the case of axial force, and a proportion of the eaves moment assumed to be 50% of the moment of a fixed base. This represents a moment that is halfway between a fixed and a pinned condition. The tensile force of 13.85 kN is much smaller than the tensile resistance of a holding-down bolt

(67.85 kN). The holding down bolt provides the tensile resistance required to maintain equilibrium. The 150×90 ×10 mm angle is connected to the foundation using an M20 Grade 8.8 bolt and to the column using 2M20 Grade 8.8 bolts. Tests have shown this angle to be capable of transferring the load from the column into the foundation

(Dundu and Kemp, 2008; Dundu and Maphosa, 2010). 9. Serviceability Requirements of Portal Frames

It is imperative that an analysis at the serviceability limit state be carried out to check deflections at both eaves and apex. Although the service loads are notably

smaller than the ultimate loads on a structure, the magnitude of deflections of a structure under service loads may be as important a design consideration as the

strength of a structure under ultimate loads. The check is required, not only to ascertain whether deflections are excessive, but also as a check to ensure that the deflections and accompanying frame movements can be accommodated by the building envelope without undue cracking of any brick or tearing of metal cladding sheets at fixed positions. Since the use of cold-formed steel portal frames is limited

to light industrial buildings without gantry cranes, there are only three main considerations for deflection limits;

(1) Horizontal deflection at the eaves should not cause damage to the cladding or brickwork.论文网

(2) The difference in horizontal deflection at the eaves between the end frame and the adjacent internal frame is often a problem as the end frame not only carries half the load of the internal frames but is also much stiffer as a result of the sheeting and internal columns within the end frame. This is exacerbated by the fact that the same section sizes and details used for the internal frames are often used for the end frames. Differential horizontal deflection at the eaves should not be excessive, otherwise significant stressed skin action will develop. Fixings may

上一篇:对木桥的负载和阻力系数的校准英文文献和中文翻译
下一篇:利用地板下的空气提高建筑的可持续性空调系统英文文献和中文翻译

锈蚀钢筋的力学性能英文文献和中文翻译

未加筋的低屈服点钢板剪...

钢筋混凝土柱抗震性能试...

不锈钢钢管混凝土的实验...

钢筋混凝土倒T梁采用锚固...

层残余应力钢钛刀具磨损英文文献和中文翻译

舰船玻璃钢夹芯板缺陷和...

浅论职工思想政治工作茬...

酵母菌发酵生产天然香料...

从政策角度谈黑龙江對俄...

基于Joomla平台的计算机学院网站设计与开发

压疮高危人群的标准化中...

AES算法GPU协处理下分组加...

提高教育质量,构建大學生...

浅谈高校行政管理人员的...

上海居民的社会参与研究

STC89C52单片机NRF24L01的无线病房呼叫系统设计